The Universal AutoDual ® is so effective it typically allows end users to recover the capital outlay of their entire compressor purchase within 3 years in energy savings alone. Here's how we do it:
Example: A savings analysis of a 25 HP, 2 stage, reciprocating or rotary screw compressor operating a factory that is producing 7 days per week on three shifts (8760 hours per year).
Basis
25 HP = 23 KW x motor P.F. of 1.15 (power factor) = 26.45 KW
Unloaded KW = Full Load KW (26.45KW) x
Unloaded KW (25%) x losses (part load motor efficiency
& power factor = 35% efficiency loss
Unloaded KW = 26.45 x 25 = 10.17KW
.65
1st Shift: 75% Loaded, 25% Unloaded
2nd Shift: 40% Loaded, 60% Unloaded
3rd Shift: 20% Loaded, 80% Unloaded
Electric Rate: $.10/KWH
Unloaded kW: 25% of Full Load = 10.17KW at
8760 hours per year
Unloaded kW Savings
1st Shift: 2920 hours x .25 x 10.17 x .10 = $743
2nd Shift: 2920 hours x .60 x 10.17 x .10 = $1782
3rd Shift: 2920 hours x .80 x 10.17 x .10 = $2375 Total Annual Power Savings: $4900**
**In areas of higher KWH rates, such as Metro New York, at 0.15/KWH, the annual savings would be $ 7350.00/yr
Total Annual Electric Energy Savings = 49,000 KwHrs/year
**In areas of higher KWH rates, such as Metro New York, at 0.15/KWH, the annual savings would be $7350.00/yr.
Copyright © 2019 Standard Pneumatic Products, Inc. , 31 Shepard Hill Rd., Newtown, CT 06470 USA, 203-270-1400 - All Rights Reserved.
Powered by GoDaddy Website Builder